X.25/9000 Link
Technical Data
For the HP9000 Series 300/400: product number 36941A
Series 700 : J2159A
Series 800 : 36960A
The X.25/9000 Link product for the HP9000 Series 300/400,
700 and 800 provides a network connection on the HP9000
Series 300/400, 700 or 800 to private and public X.25
networks. This product conforms to the 1984 CCITT
recommendations.
This product allows HP9000-to-HP9000 communications as well
as HP9000 to other systems (HP or non-HP) over X.25
networks, through the use of ARPA services, Unix - to - Unix
Copy (UUCP), OSI and SNA over QLLC . ( SNAplusLink is only
available on Hp9000 s/700 and s/800).
Remote display terminals are supported by implementation of
host PAD capability (CCITT recommendation X.3 and X.29) on
the X.25/9000 Link product. Host PAD emulation and remote
PAD printer is also supported by the X.25/9000 Link product.
NFT, HP's Networking Services product is supported for
communications between HP9000s or between HP9000s and
HP3000s, (MPE/V and MPE/XL). In addition, the X.25/9000
Link product provides programmatic access (through Berkeley
sockets) to X.25 packet layer 3 and via TCP provides access
to HP's NetIPC. This allows customers to develop their own
protocol and services for communications with remote HP or
non-HP systems over an X.25 network.
The X.25/9000 Link product supports OSI services environment
when implemented with the OTS/9000 product. The X.400/800
product allows customers to exchange electronic mail using
the X.400 protocols over the X.25/9000 Link (Series 800
only).
FEATURES and BENEFITS
* Compliance with industry and international standards
-Supports ARPA/Berkeley Services (except ruptime and
rwho) for HP9000 computers over the X.25/9000 Link
-Supports NFT for HP9000-to-HP9000, HP9000-to-HP3000/V
and HP9000-to-HP3000/XL communications
-Supports layer 3 interoperability for HP9000-to-
HP1000, HP9000-to-HP3000/XL and HP9000-to-HP3000/V
communication
-Provides ability to write customized programs to layer
4 over TCP/IP via BSD and NetIPC. (ARPA Services/9000
are required for application development using Berkeley
services
-Implements industry-standard Defense Advanced Research
Project Agency (DARPA) TCP/IP protocols
-Complies with the 1980 and 1984 CCITT recommendation
for X.25
-Complies with the U.S. Defense Data Network (DDN)
TCP/IP-X.25 standard protocols
* Customized application support
-Provides programmatic user access to X.25 packet layer
3 for multivendor and customer-designed communications
via Berkeley Sockets.
* Ease of Use
-Extensive diagnostic tools
-Menu driven configuration product
* Cost-effective remote terminal connections
-Implementation of host PAD capability (complies with
the 1984 CCITT recommendation X.3 and X.29)
-Provides PAD Emulation for incoming and outgoing
access
-Provides remote PAD printing capabilities
* Transparent access over multiple nodes and networks
-Dynamic packet routing and gateway capabilities
through the use of Arpa/Berkeley services over Internet
Protocol (IP)
-Dynamic packet routing and gateway capabilities
through the use of Open Systems Interconnection OSI
when used with X.400
-Provides interface with Unix-to-Unix copy (UUCP)
SUPPORTED X.25 NETWORK PARAMETERS
Layer 1
o X.21 bis (RS232-C, CCITT V.24/28) for line speed from 1200
bps to 19.2 Kbps
o V.35 (Series 700/800 only) for line speed from 1200 to 64
Kbps
o Operates as a DTE
Layer 2
o LAP-B protocol
o Frame sizes: as required for layer 3 packet sizes
o Window sizes: 1-7
o Modulo 8 and 128 frane sequence numbering
o Configurable maximum number of retransmissions (0-255)
o Configurable retransmission timer (1 to 12 sec)
o Operates as a DTE or DCE
Layer 3
o One-way/two-way (incoming and outgoing) Switched Virtual
Circuits (SVC)
o Permanent Virtual Circuits (PVC) (not supported in a host PAD
support configuration
o Delivery confirmation bit (D-bit) for X.25 packet level 3
applications only (series 700/800 only)
o Qualifier bit (Q-bit) for X.25 packet level 3 applications
o More-data bit (M-bit)
o Packet sizes: 128 or 256 bytes for Series 300/400
16 to 4096 bytes for Series 700/800
o Window sizes: 1-7
o Maximum Virtual Circuits: 32 (128 byte packets) for Series 300/400
64 (128 byte packets) for Series 800 (Mid-Bus)
o Modulo 8 and 128 packet sequence numbering
o Throughput class: 3 to 11 for Series 300/400; 3 to 12 for Series
700/800
o Operates as a DTE or DCE
SUPPORTED and RECOMMENDED PRODUCTS
Certified X.25 Packet Switched Networks.
Operation of the X.25/9000 product connected to a public X.25
Network requires certification on this Network.
The X.25/9000 product is certified on many X.25 Public Networks.
In order to get the most up to date certified X25 Networks list
(based on HP/9000 platforms and HP-UX versions) please contact
your Sales Response Center.
VERIFIED MODEMS
____________________________________________________________
MODEM VERIFIED SPEED(S), Bps
____________________________________________________________
Black Box SME V.35 1200,7200,64000
CIT Alcatel V35 ER BdB 144/20 48000,64000
CODEX 2345 4800, 7200, 9600
HP 37230A 4800, 7200, 9600, 19200
Racal Milgo MPS 1222 9600
____________________________________________________________
VERIFIED X.25 SWITCHING EQUIPMENT
HP Model 45
HP Model 45 Plus
SUPPORTED PAD DEVICES
HP 2334A Plus
HP 2335
Note: HP 2334A Plus and HP 2335A HP-defined local PAD
parameters are not supported.
SUPPORTED TERMINALS AND PCs (for use in host PAD
configuration)
* HP 700/41
* HP 700/92
* HP 700/94
* HP 700/22
* HP 2392A
* HP 2393A
* HP Vectra (used with AdvanceLink and Reflection terminal
emulation)
SUPPORTED APPLICATIONS (for use in host PAD configuration)
All HP-UX applications, with the exception of block-mode
applications, and mail exchange.
INTEROPERABILITY
The following configurations have been tested and are
currently supported:
______________________________________________________
Level 3 NS ARPA
______________________________________________________
HP9000-to-SUN X X
HP9000 through
Cisco AGS router X X
HP9000-to-HP1000 X
HP9000-to-HP3000/V X X
HP9000-to-HP3000/XL X X
______________________________________________________
CONFIGURATION REQUIREMENTS
Series 300/400
* HP-UX Operating System Version 8.0 or later
(X.25 and HP-UX versions must be the same)
* Minimum Central Memory: 4 Mbytes
* Minimum free disk space: 2.4 Mbytes
* Supported Processors: 320, 330, 332, 340, 350, 360, 370
Series 700
* HP-UX Operating System Version 8.05 or later
(X.25 and HP-UX versions must be the same)
* Minimum central memory: ???
* Minimum free disk space: ???
* Supported processors: 715, 720, 730, 750
Series 800
* HP-UX Operating System Version 8.0 or later
(X.25 and HP-UX versions must be the same)
* Minimum central memory: 8 Mbytes
* Minimum free disk space: 3.4 Mbytes
* Supported processors: 807, 808S, 815S, 817, 822, 825S,
825SRX, 825CHX, 827, 832, 837, 835S, 835SE, 835SRX, 835CHX,
840S, 842, 845, 847, 850S, 852, 855, 857, 860, 865, 867, 870
877, 887, 890, 897
INSTALLATION POLICY
Customer Installation and Configuration
The customer is responsible for the installation of the
X.25/9000 Link product.
Before installing X.25/9000, the customer should obtain,
install and verify the correct operation of any
communication line, X.25 network access or any other
equipment and facilities necessary to interface to the
X.25/9000 Link product.
Hewlett-Packard is only liable for the correct execution of
the product self-tests. All other hardware and software
connections to the communication line, the X.25 network and
non-HP computers are the customer's responsibility.
PRODUCT STRUCTURE
The X.25/9000 Link product includes an X.25 networking card,
software, customer documentation and the necessary cables
for connection to the customer's modem.
ORDERING INFORMATION
Series 300/400
36941A X.25/300 and X.25/400 Link for the HP 9000 Series 300
and Series 400; includes an RS-232-C (DTE) cable (5m) and
software
Opt. 1AW Credit for software; used if an additional X.25
card is needed in the SAME HP9000
Series 700
J2159A X.25/9000 Link for the HP9000 Series 700
Media Options.
UJ8 - 1/4 inch cartridge tape
Connection Options.
1AT - RS232-C cable
1AU - V.35 cable
Documentation Options.
0B0 - Delete all manuals
Hardware Only Option.
1AW - Delete software. For additional cards only.
Series 800
36960A X.25/9000 Link for the Series 800
Must order ONE feature in the following options:
Processor License Options:
AH0 License to use on the 807/808/817/F/G servers
AEL License to use on the 815/822/827/837
AE5 License to use on the 825/832/847/857/H/I servers
AE6 License to use on the 835/835SE/842/867/877
AEN License to use on the 840/845/852
AEP License to use on the 850/855/860/865/870-100/890-1/890-2
AH1 License to use on the 870-200/870-300/870-400/890-3/890-4
Processor Hardware Options:
20N For 807/808/815/817/822/827/832/837/842/847/852/857/867/877
887/890/897
20C For 635/645/825/835/840/845/850/855/860/865/870
Media Options:
Documentation is included when a media option is selected.
AA0 Software on 1/4" cartridge tape
AA1 Software on 1/2" magnetic tape (1600 bpi)
AAH Software on Digital Audio Tape (DAT)
Interface Cable Options:
1AT RS-232-C (DTE) cable (5m)
1AU V.35 cable (5m, Series 700/800 only)
Note: This cable complies with the U.S. standard which does
not comply to European standards. A universal adapter is
required for complying to European standards.
MAY order ONE feature in the following options:
Documentation Options:
0B0 Deletes all the manuals
Hardware Only, Credit Options:
1AW Deletes software on the 807/808/817 processor
2A1 Deletes software on the 815/822/827/837
2A2 Deletes software on the 825/832/847/857
2A3 Deletes software on the 835/835SE/842/867/877
2A4 Deletes software on the 840/845/852
2A5 Deletes software on the 850/855/860/865/870(100)
2A6 Deletes software on the 870 Multiprocessing Models
Software Upgrade, Credit Options:
Requires previous purchase of X.25 Link for the Series 800.
Upgrades are allowed only for SPU's within the same
Processor Hardware Option (see 20N and 20C above).
0GR Return Credit for X.25/800, From Model 807/808/817
0GE Return Credit for X.25/800, From Models 815/822/827/837
0G8 Return Credit for X.25/800, From Models 825/832/847/857
0GS Return Credit for X.25/800, From Models 835/835SE/842/867/877
0GT Return Credit for X.25/800, From Models 840/845/852
0GU Return Credit for X.25/800, From Models 850/855/860/865/870(100)
Additional cables may be ordered:
28606-63006 RS-232-C
28606-63003 V.35 (for Series 800 only)
Note: This cable complies with the U.S. standard which does
not comply with European standards. A universal
adapter is required to comply with European standards.
The X.25/9000 Link for the Series 800 is also available as
" factory-installed " for the F/G/H/I Servers . Only one
link product may be ordered using this ordering option.
0DN Factory installed X.25 link with RS232 interface on F or G server
0DP Factory installed X.25 link with V35 interface on F or G server
0DQ Factory installed X.25 link with RS232 interface on H or I server
0DR Factory installed X.25 link with V35 interface on H or I server
SUPPORT PRODUCTS
H2012A+L00 BaseLine Software Support
H2011A+H00 ResponseLine Software Support
H2010A+T00 Teamline Software Support
H2014A+S00 Software Update Materials
Customers with ResponseLine and Teamline support for the HP-
UX Operating System will automatically receive this same
level of support (ResponseLine and Teamline) for the
X.25/9000 Link product. Customers with hardware support
agreements must add the appropriate level of coverage
(Priority , Priority Plus or Next Day Service) for this link
product to their support agreement.
DOCUMENTATION
The following Hardware installation manuals are included
with each product:
Series 300/400:
36941-90002 X.25/300 Link Hardware Installation Manual
Series 700:
25565-90001 EISA (PSI) Programmable Serial Interface Adapter
Installation and Administratiion Manual
Series 800:
30263-90001 Series 800
(825/835/840/845/850/855/860/865/870) Central Bus PSI Card
Installation Manual
28606-90001 Series 800 Models 808/815/822/832/842/852 HP-
PB Programmable Serial Interface Hardware Installation Guide
The following manuals are included with all X.25/9000 Links.
Additional copies may be ordered from HP:
36940-90001 X.25/9000 Programmer's Guide
36940-90004 Installing and Administering X.25/9000
36940-90005 Troubleshooting X.25/9000
5958-3402 X.25: The PSN Connection
Related Documentation
The following manuals may be ordered separately:
98194-60527 NetIPC Programmer's Guide
98194-60525 Berkeley IPC Programmer's Guide